Data Logger Programming
Exercise I
Sensor: Temperature-Humidity Probe
Sampling interval: 10 min
Final storage: 1 hour
Statistics: average, max, min, standard deviation
Date: year, month day, hour (for each final
storage)
Use table 1 for the sampling rate
Print data logger program
Connect data logger to NT station in COM1 port
Set data logger time same as computer time
Upload program from computer to data logger
Exercise II:
Sensors: 3 Temperature/Humidity sensors
Sampling interval 1: 1 min (for two sensors)
Final storage 1: 10 min
Statistics 1: average
Date: hour, min (for each final storage)
Sampling interval 2: 10 min (for one sensor)
Logger Voltage 3 hours
Final storage 2: 3 hours
Statistics: average, min, max
Date: year, month, day, hour (for each final
storage)
Use table 1 and 2 for the different sampling
rates
Print data logger program
Connect data logger to NT station in COM1 port
Set data logger time same as computer time
Upload program from computer to data logger
Hand-in data logger printout
from Exercise I and II next week (Sept. 18)
|